Water analysis panel

New

Multi-parameter measuring system for water quality monitoring

  • Flexibility in selecting different water parameters: Dissolved oxygen, turbidity, conductivity, pH/ORP
  • Installation on compact analytical modules: All measuring points at one location
  • Completely pre-wired and pre-assembled for easy bypass installation

Water analysis panel

Water analysis panel

The water analysis panel is a multi-parameter measuring system for applications in water treatment. It consists of single modules that can be combined for measuring dissolved oxygen, turbidity, conductivity, pH and ORP. Depending on the requirements, the measuring system can thus be operated as a complete solution or with selected modules allowing configuration of different sensor types. This provides a high degree of flexibility in accordance with the application requirements. The pre-assembled and pre-wired analysis panel enables easy installation and fast commissioning. In this way, complexity and installation effort are significantly reduced as compared to spatially separated measuring points.

Product highlights

  • Continuous monitoring of water quality at one single measuring point
  • Application-specific selection of analytical parameters
  • Free configuration of sensor types for high flexibility
  • Simple and cost-effective installation
  • Pre-assembled and pre-wired for fast commissioning
  • With PVC or stainless steel panel material

Typical applications

Water industry

  • Monitoring of drinking water quality in pumping stations
  • Filter monitoring
  • Process control in water treatment Monitoring of limit values
  • Demineralisation
  • Monitoring water quality prior to discharge into the water supply network

Product variants

Analytical module for turbidity measurement with stainless steel panel

Analytical module for turbidity measurement

  • Analytical panel with OPTISYS TUR 1060 turbidity measuring system
  • 90° scattered infrared light measurement (ISO 7027) or white light measurement (EPA 180.1): 0…100 NTU/FNU
  • Output: 4…20 mA, 2 alarm relays or Modbus via RS485; integrated data logger
Analytical module for dissolved oxygen or inductive conductivity measurement with stainless steel panel

Analytical module for dissolved oxygen or inductive conductivity measurement

  • Analytical panel with transmitter and flow-through assembly for measuring dissolved oxygen or conductivity (inductive)
  • Optical oxygen measurement: 0…20 mg/l
  • Inductive conductivity measurement (electrodeless, with temperature compensation): 1…2000 mS/cm
  • Output: 3 x 4…20 mA, 3 relays (mechanical)
Analytical module for pH, ORP and conductive conductivity measurement with stainless steel panel

Analytical module for pH, ORP and conductive conductivity measurement

  • Analytical panel with transmitter and measuring cells for measuring up to two different parameters simultaneously
  • pH: 0…14; Redox: -1500…+1500 mV;
    Conductivity (conductive): 1…2000 µS/cm or 0.1…20 mS/cm
  • Output: 3 x 4…20 mA, 3 relays (mechanical)

Related products

OPTISENS PH 8100

Potentiometric pH sensor for chemicals, industrial wastewater and low conductivity media (>2 μS/cm)

  • For use with analytical transmitter
  • Process connection: PG13.5
  • 0…14 pH; Max. +130°C / +266°F; 10 bar / 145 psi
  • Glass sensor with 2 open diaphragms and Pt100 for temperature compensation

View product details

OPTISENS PH 8300

Potentiometric pH sensor for wastewater, surface and process water applications

  • For use with analytical transmitter
  • Process connection: PG13.5
  • 0…14 pH; Max. +70°C / +158°F; 10 bar / 145 psi
  • Glass sensor with PTFE diaphragm and optional Pt100 for temperature compensation

View product details

OPTISENS PH 8500

Potentiometric pH sensor for potable water applications

  • For use with analytical transmitter
  • Process connection: PG13.5
  • 0…14 pH; Max. +70°C / +158°F; 2 bar / 30 psi
  • Glass sensor with ceramic diaphragm and optional Pt100 for temperature compensation

View product details

OPTISENS ORP 8500

Potentiometric ORP sensor for water and wastewater applications

  • For use with analytical transmitter
  • Process connection: PG13.5
  • -1500…+1500 mV; Max. +70°C / +158°F; 2 bar / 30 psi
  • Glass sensor with platinum electrode and ceramic diaphragm

View product details

OPTISENS IND 1000

Inductive conductivity sensor for water, wastewater and chemical applications

  • For use with analytical transmitter
  • Process connection: G1½ union nut and immersion versions
  • 1…2000 mS/cm; Max. +100°C / +212°F
  • Electrodeless conductivity sensor with Pt1000 for temperature compensation

View product details

OPTISENS ODO 2000

Optical oxygen sensor for water and wastewater applications

  • For use with analytical transmitter
  • For immersion or insertion
  • 0…20 mg/l; Max +50°C / +122°F; 6 bar / 87 psi
  • With rugged PVC sensor body, available with spray cleaning nozzle (immersion version)

View product details

OPTISYS TUR 1060

Optical turbidity measuring system for potable water applications

  • 4-wire, 4…20 mA, 2 alarm relays or Modbus via RS485; built-in data logger
  • For online bypass installation
  • 0…100/1000 NTU/FNU; max. +50°C / +122°F; 7 bar / 101 psi
  • 90° scattered infrared light (ISO 7027) or white light (US EPA 180.1)

View product details

SENSOFIT FLOW 2000 Flow Cell

Flow-through assembly for water and wastewater applications

  • For use with optical oxygen and turbidity sensors OPTISENS ODO and TUR 2000 (inline versions)
  • Sensor connection: union nut; Process connection: hose connection
  • For measurement in small sample streams
  • Max. +50°C / +122°F and 6 bar / 87 psi

View product details

MAC 100

Liquid analytical transmitter for measurements with sensors of the OPTISENS portfolio

  • Output: 3 x 4…20 mA, 3 relays (mechanical)
  • Input: max. 2 x sensor, 2 x temperature
  • -15…+55°C / +5…+131°F (ambient)
  • Robust housing for wall-mount installation

View product details